Brand Name : LionRock

Model Number : LRT2535

Place of Origin : Dongguan China

Payment Terms : TT

MOQ : negotiate

Price : negotiate

Packaging Details : export packing

Delivery Time : negotiate

Color : Blue

Length : 6250

Width : 2250

Height : 2850

Weight : 14500

Fuel Tank : N/A

Contact Now

LionRock Generator sets are suitable for commercial, industrial, telecom, Data Centre and infrastructure application.

Standard features

- Set mount radiator with engine driven fan
- Cooling system standard for 40°C ambient
- Anti-vibration mounts between engine / alternator and baseframe
- Baseframe fuel tank
- Protective grille for fan and rotating parts
- Exhaust bellow and industrial silencer
- 24VDC starter motor and battery
- Generator sets are CE Certified
- Standard 3P manual output breaker
- Coolant and oil drains with valve
-
Each LionRock® generating set will go through factory test at 0%, 25%, 50%, 75%, 100% and 110% of rated capacity

Standard and Quality

- All generator sets comply with international standards including ISO8528, ISO3046, IEC60034, BS5000
- Manufacturing standard certified to ISO9001, ISO14001, ISO18001

- CE certificate for generator set

Rating definition as per ISO8528

- Prime - Output available with varying load for an unlimited time. Average power output is 70% of the prime power rating. Typical peak demand is 100% of prime rated kWe with 10% overload capability for emergency use for a maximum of 1 hour in 12.
- Standby - Output available with varying load during a normal power supply failure. Average power output is 80% of the standby power rating. Typical annual operating time less than 500hours. No overload is available.

Power Ratings at 0.8 power factor
Voltage(V)
Standby

Prime

Maximum current(Amp)
kVA
kW
kVA
kW
380/220
2525
2020
2280 1824 3836
400/230
2525
2020
2280 1824 3644
415/240
2525
2020
2280 1824 3521

Fuel Consumption
Load (%)
Standby
100 75 50
(L/h)
515 468 356 243

Standard 3P Manual Output Breaker AC Mitsubishi 50Hz Diesel Generating Sets

Dimensions
Weight
Fuel Tank
Length (L)
Width (W)
Height (H)
Dry
Baseframe
mm
mm
mm
kg
litres
6250 2250 2850 14500 N/A

Technical data
Mechanical measurement
- Water temperature
- Oil Pressure
- Engine speed
- Running hours
- Number of start
- Battery voltage
Electrical measurement
- Voltage (P-P, P-N)
- Current
- Frequency
- Power factor
Communication
- USB (Programming)
Energy Meter
- kW/kWh/kVA
Protection
- Overspeed
- High coolant temperature
- Low oil pressure
- Start up failure lock out
- Emergency Stop
- Over and under frequency
- Over and under voltage
- Overload
- Overcurrent
Control
- Auto/Manual
- Start/stop button
- Alarm/fault acknowledge
- Menu button
- Display navigation buttons
Protection
- Overspeed
- High coolant temperature
- Low oil pressure
- Start up failure lock out
- Emergency Stop
- Over and under frequency
- Over and under voltage
- Overload
- Overcurrent
Control
- Auto/Manual
- Start/stop button
- Alarm/fault acknowledge
- Menu button
- Display navigation buttons
Features
- Automatic mains failure
- Fuel tank content in %
- Oil temperature gauge
- Modbus SNMP
- Modbus TCP/IP Ethernet
- Extended input/output modules
- RS485 Modbus
Alternative control modules
- Wide range of control module options including:
ComAp
Deepsea
Woodward
Smartgen etc.
- Multiple generators parallel as well as parallel with mains power
Soundproof Canopy
Standard 3P Manual Output Breaker AC Mitsubishi 50Hz Diesel Generating Sets
Dimensions and Weights
Length (L): mm
12192
Width (W): mm
3000
Height (H): mm
3370
Weight: kg
22033
Fuel Tank Capacity: litres
N/A

Sound Pressure Levels
75% Load
50Hz
Prime: dBA@1m
94
dBA@7m
83
dBA@15m
77

Stainless steel locks and handles on doors
- Black zinc die cast hinges on doors proven to withstand extreme weather conditions
- Zinc plated standard fastener with stainless steel option
- Enclosure made of sheet steel pre-treated with zinc phosphate prior to polyester powder coating
Secure, lockable doors prevent unauthorized access to control panel, fuel fill and battery
- Emergency stop buttons mounted on enclosure exterior surface
- All moving parts including Cooling fan, charging alternator, belt are fully guarded
Hinged doors of 180 deg swing on both sides of the enclosure for easy access and maintenance
- Lube oil and water drains hosed to baseframe side to exterior
- Removable end panels allow access to radiator, exhaust silencer and alternator rear
- Exhaust silencer inside enclosure
Easy Transportable
- Lifting points on both side of baseframe
- Anchor and drag points at baseframe ends

Quality Standard 3P Manual Output Breaker AC Mitsubishi 50Hz Diesel Generating Sets for sale

Standard 3P Manual Output Breaker AC Mitsubishi 50Hz Diesel Generating Sets Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: 3tech corporate limited
*Subject:
*Message:
Characters Remaining: (0/3000)